Add to Cart
3.0mm Aqua Mini Type Fiber Optic Jumper Cable For MTP MPO Assemblies
Jacket Characteristics:
Operating Temperature | -40 to +85 |
Storage Temperature | -40 to +85 |
Installation Temperature | 0 to +60 |
Flame Retardancy | UL Listed Type OFNP (ANSI/NFPA 262) and FT6 (CSA C22.2 No. 232) |
Crush Resistance | 1,500 N/cm |
Impact Resistance | Per ICEA-S-83-596 |
Flex Resistance | 1,000 cycles |
Specifications:
Fiber Count | Diameter | Weight kg/km (lbs/1,000ft) | Tensile Load | Minimum Bend Radius | ||
Installation N (lbs) | Operational N (lbs) | Installation cm (in) | Operational cm (in) | |||
12 | 6.5 (0.26) | 45 (30) | 2,700 (600) | 900 (200) | 9.8 (3.8) | 9.8 (3.8) |
Applications:
Used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces;
Ideal configuration for a single termination point requiring multiple fibers.
Features:
High performance components and construction;
High specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls;
Helically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers;
Lower installed cost;
High performance tight-buffered coating on each fiber for environmental and mechanical protection;
High crush resistance may eliminate the need for innerduct;
900 μm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber;
UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces.
Indoor/Outdoor ("K" Jacket)
Indoor/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments;
Cable materials are UV, water and fungus resistant;
Higher fiber counts available than similar cables available by others in subgrouped configuration;
Jacket is highly chemical resistant for installation in harsh industrial environments;
Interlocking armor can be applied to cables as an alternative to conduit installation;
Can be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments;
2 to 72 fiber configuration is smaller and lighter than comparable sub-grouped cables, which is ideal for installation in areas with limited space or tight bends.
Standards List:
UL 1651
ANSI/NFPA 262
GR-409-CORE
ICEA-S-104-696
ICEA-S-83-596
TIA-568
TIA-598
Shipping Tools By:
Quality Control:
Contact Us:
Prices and specifications are subject to change without notice. FOCC is not responsible for typographical or photographic errors. For more details please contact us focc@fiberfocc.com directly, your choices are under our best service.