Fiber Optic 12 Strand FC Fiber Optic Patch Cord With MTP Female to FC APC Polish
For user obtain accurate and repeatable results measuring insertion and return loss, the reference connector needs to outperform the connector under test. Reference cables from FOCC are produced with reference ends that are certified to exceed the FOTP171A (A2.2.1) standard.FOCC MTP cables are available in hybrid / fanout configurations or in MTP-to-MTP varieties. Any MTP connector can be male or female and the reference end exceeds the requirements of FOTP171A (A2.2.1). Any simplex connector on a hybrid cable (FC, SC, LC, etc.) will meet the standards requirements for the specified connector and polish type (APC or UPC). For additional connector types or custom configurations, please contact FOCC freely, we as a professional team to service with you. This is a 62.5um OM1 multimode reference cable with 12 FC/APC connectors on one end and a 12-channel MTP connector on the other end.
Features & Benefits
Plug and Play;
Transition from Trunk Backbone to Fiber Rack;
12 Cores Configuration (Custom Order Option);
65 - 75% space reduction compared to traditional Patch Cords;
MPO fan-outs numbered for traceability;
Test Report with each assembly.
Application
Local Area Networks;
Data Centres;
Campus Networks;
Storage Area Networks.
Cables Specification
MTP Cables |
MM PC (850nm / 1300nm) |
SM APC (1310nm / 1550nm) |
Insertion Loss |
< 0.25dB |
|
Return Loss |
40dB (50μm) 35dB (62.5μm) |
70dB |
Fiber height |
1000nm to 1700nm |
|
Max Variation in Fiber Height |
500nm |
|
Max Adjacent Fiber Height Differential |
200nm |
|
Core Dip |
< 30nm |
MTP / MPO Termination
Type |
Singlemode (APC polish) |
Singlemode (PC polish) |
Multimode (PC polish) |
|||
Fiber Count |
4,8,12, 24 etc. |
4,8,12, 24 etc. |
4,8,12, 24 etc. |
|||
Fiber Type |
G652D,G657A1 etc. |
G652D,G657A1 etc. |
OM1,OM2,OM3 etc. |
|||
Maximum Insertion Loss |
Elite Low Loss |
Standard |
Elite Low Loss |
Standard |
Elite Low Loss |
Standard |
≤0.35 dB |
≤0.70 dB |
≤0.35 dB |
≤0.70 dB |
≤0.35 dB |
≤0.50dB |
|
Return Loss |
≥55 dB |
≥45 dB |
≥20 dB |
|||
Durability |
≥200 times |
≥200 times |
≥200 times |
|||
Operating Temperature |
-40℃~ +80℃ |
-40℃~ +80℃ |
-40℃~ +80℃ |
|||
Test Wavelength |
1310nm |
1310nm |
850nm |
Generic Connector Termination
Type |
Singlemode |
Multimode |
|
Fiber Type |
G652D,G657A1 etc. |
OM1,OM2,OM3 etc. |
|
Maximum Insertion Loss |
UPC |
APC |
UPC |
≤0.30 dB |
≤0.30 dB |
≤0.30 dB |
|
Typical Insertion Loss |
0.2 dB |
0.2 dB |
0.2 dB |
Return Loss |
≥50 dB |
≥55 dB |
≥25 dB |
Durability |
≥500 times |
≥500 times |
|
Operating Temperature |
-40℃~ +80℃ |
-40℃~ +80℃ |
|
Test Wavelength |
1310nm |
850nm |
More Options
Shipping Terms or Customized Requirements
FOCC Fiber Patch Cables Guarantee
Specifications are subject to change, please confirm specific performance characteristics of the product at the time of ordering. All specifications are valid within temperature range of 18ºC to 24ºC unless otherwise noted. For additional specifications please contact focc@fiberfocc.com or calling 0086-755 36933697.